Guided Implant Surgery Kits

Guided Implant Surgery Drill Kits

We manufacture 50-, 53- and 56-piece guided implant drill kits to an approved compatibility schedule for distributors, OEM programs and clinical procurement teams. Each quotation can define drill diameters and lengths, sleeve or key interface, depth-control components, drivers, torque tools, replacements and the mapped cassette contents.

Product code
DIS-IMP-GUIDE-GRP
Material
Stainless steel; component-specific material confirmed with the quotation
Options
4 available
MOQ
confirmed with your quote
Pricing
Request quotation

Include the required pattern, quantity, finish, packaging and destination. We confirm the exact product and commercial terms before production.

Product photography pendingApproved images for Guided Implant Surgery Drill Kits will appear here without changing the page layout.

About Guided Implant Surgery Drill Kits

Our guided implant surgery drill kits are built to a documented drill, guide and driver interface rather than sold on a vague claim of universal fit. We offer 50-, 53- and 56-piece configurations that combine drill sequences, depth-control parts, positioning components, drivers and an organized cassette. Before production, we compare the buyer's guide or sleeve data with the proposed component schedule and identify every dimension that still needs approval.

Compatibility Comes Before Piece Count

A 50-, 53- or 56-piece label describes the nominal configuration, not the system it will fit. Compatibility depends on the relationship between the guide sleeve or key, drill body, working length, stopper or depth-control design, handpiece shank and implant driver connection. A kit should therefore be purchased from a dimensional schedule, not from the product title or case photograph alone.

We do not use the word “universal” as a substitute for this review. If you are matching an established guided system, provide the manufacturer or system reference together with the measurable interface data available to you. Any compatibility statement in our offer will be limited to the dimensions and components that have actually been checked.

Compare the 50-, 53- and 56-Piece Configurations

  • **50-piece multi-instrument configuration:** combines conical stopper drills with listed bone expanders, external-irrigation drills, trephines, tissue punches, compression screws, drivers, a depth gauge and torque wrench.
  • **53-piece guided configuration:** organizes a guided drill sequence with its corresponding driver storage and configuration-specific supporting parts.
  • **56-piece configurations:** provide multiple drill diameters and working lengths together with depth pins, lance drills, torque components and supporting adapters as defined by the selected SKU.

These summaries help identify the families, but the final contents are shown in a bill of materials. Similar piece counts can still contain different diameter progressions, lengths or interfaces, so we confirm each case position before the order is approved.

Drill Sequence and Working-Length Data

For every drill in the proposed sequence, the specification can record its diameter, cutting or working length, overall length, shank, depth-control method, surface treatment or coating where required, and case position. If your system uses a separate sleeve key, reduction insert or guide key, include its inner diameter, outer diameter and relevant offset dimensions.

Depth control may be provided by configuration-specific stoppers or guided working lengths. The measurement reference must be clear so that the listed length and the buyer's expected reference point describe the same geometry. We request approval of this schedule instead of deriving it from color coding alone.

Drivers, Torque Components and Supporting Parts

Driver fit requires the implant connection and the intended handpiece or manual interface. Where torque components are included, the quotation identifies the component and requested range or markings without providing procedural settings. Positioning pins, lance drills, adapters, tissue punches, trephines and other supporting items are listed only when they belong to the selected configuration.

If your purchasing list requires only part of a standard set, we can review a custom component map. Minimum order quantity will depend on the number of custom components, markings, coating, cassette changes, packaging and private-label requirements.

Replacement Drills and Case Mapping

Individual drills or accessories can be quoted as replacements after the parent kit and component are identified. Send the kit SKU, case position, drill diameter, working length, shank, stopper or sleeve relationship, and any etched or color reference. We verify the replacement against the recorded specification rather than assuming that two visually similar drills are equivalent.

The cassette map forms part of the product definition. It can identify each position by sequence, size and component code, helping your receiving team check the shipment and your purchasing team reorder a missing item. Case material, layout, labels and sterilization-related information are confirmed for the ordered configuration and supporting instructions.

Materials, Markings and Procurement Evidence

We confirm drill and instrument material grades, requested coatings, dimensional tolerances and available material evidence against the approved order. Size marks, position codes, branding and label artwork can be reviewed before production. Our manufacturing operates under ISO 9001:2015 quality management certification; the certificate and agreed order documentation can be supplied to support vendor qualification.

Details Needed for a Reliable Quotation

Send the guide system reference, sleeve or key dimensions, required drill diameters and working lengths, depth-control method, shank and handpiece interface, implant driver connection, torque-component requirements, complete or custom case contents, replacement quantities, branding, packaging, order quantity and destination. We will return a proposed component schedule and separate confirmed details from items still awaiting your approval.

Available Options

Compare the product code and attributes before requesting a quote. Choose an exact option whenever you are matching an existing order.

4 options
OptionProduct codeAttributesPricingRequest quote
50-Piece Universal Multi-Procedure KitDIS-IMP-GUIDE-GRP-50PCConfiguration: 50-Piece Universal Multi-Procedure Kit, Set Size: 50-piece configurationRequest pricingSelect for Quote
53-Piece Fully Guided Surgery KitDIS-IMP-GUIDE-GRP-53PCConfiguration: 53-Piece Fully Guided Surgery Kit, Set Size: 53-piece configurationRequest pricingSelect for Quote
56-Piece Guided Surgery Kit — Black-Coated Drill ScheduleDIS-IMP-GUIDE-GRP-56PC-BConfiguration: 56-Piece Guided Surgery Kit — Black-Coated Drill Schedule, Set Size: 56-piece configurationRequest pricingSelect for Quote
56-Piece Guided Surgery Kit — Standard FinishDIS-IMP-GUIDE-GRP-56PC-SConfiguration: 56-Piece Guided Surgery Kit — Standard Finish, Set Size: 56-piece configurationRequest pricingSelect for Quote
Have experience with Guided Implant Surgery Drill Kits?Share verified buyer or evaluator feedback.

Guided Implant Surgery Drill Kits Questions

Does universal mean a guided implant kit fits every guide system?

No. Fit depends on the sleeve or key, drill diameter and length, depth-control geometry, shank and driver connection. We limit any compatibility statement to the interfaces and dimensions checked for the quotation.

What information is required to check a guided drill kit for compatibility?

Provide the guide system reference, sleeve or key dimensions, drill diameters and working lengths, depth-control method, handpiece shank and implant driver connection. We check the proposed parts against that information before making a compatibility statement.

Can individual drills or drivers be reordered?

Yes, after the component is matched to the parent kit. Send the kit SKU, cassette position, diameter, length, shank or connection, and stopper or sleeve details for verification.